Dulux A430-Line (High Performance - Solventborne)
EPOXY CHEMICAL RESISTANT FINISH

Dulux Epoxy Chemical Resistant Finish is a two pack high build epoxy gloss finish.

USAGE
Typical uses include machinery, flooring surfaces, canteens, amenity blocks, laboratories, and workshops. It may be used in most chemicals, industrial, petrolchemical environment as well as food and beverage plant.

BENEFITS
Excellent resistance to abrasion, chemicals and salt water.

PACK SIZE 5 litres units comprising Base: 4.375 litres and Activator: 0.625 litre.

COLOUR RANGE Refer to HPC Colour Card.



Download Product Information
PERFORMANCE GUIDE
FILM PROPERTIES
Chemicalr Resistance

Heat Resistance
Water Resistance

Excellent against splashes and spillage of common acids, alkalis, solvents, and salt solutions.
Can be used on heated surfaces up to 110°C.
Excellent.
THEORECTICAL COVERAGE
A guide to the theoretical coverage which can be achieved under normal conditions is 6.7 - 10 m²/L.
PRODUCT DATA
COMPOSITION
(nominal)

Pigment : Lightfast Non-Lead Pigments and Inert Mineral Extenders.
Blinder : Polyamide Cured Epoxy.
Solvent : Alcohol and Aromatic Hydrocarbon.

VOLUME SOLIDS
50% (nominal).
FLASH POINT
22°C.
POT LIFE
Up to 6 hours at 30°C.
APPLICATION
MIXING RATIO
7 parts Base to 1 part Activator by volume.
THINNING
Brush or Roller
Conventional Spray
Airless Spray

Add up to 1 part of Dulux Thinner 850 - 761 to 10 parts of paint (10%).
Add up to 1 part of Dulux Thinner 850 - 761 to 10 parts of paint (10%).
Add up to 1 part of Dulux Thinner 850 - 761 to 10 parts of paint (10%).
SPRAY RECOMMENDATIONS
Conventional Spray
Airless Spray


Satisfactory through most equipment.
A typical set up for airless spray application is a minimum working pressure on paint of 140kg/cm² (2000 lb/sq in) with a spray tip size 0.43 - 0.58mm (17 -23 thou) and a spray tip angle of 65°.
SPRAY NOTES
It is important that the Base and the Activator are at a minimum temperature of 15°C when mixed for satisfactory spray application.
CURING TIMES
Single coat at standard thickness:
Recoat At 30°C
Full Cure

6 hours minimum.
7 days
Please note that the reaction of epoxies commences immediately the two components are mixed. This reaction is temperature related and so the curing time will be approximately halved by a 10°C increase in temperature and doubled by a 10°C decrease in temperature.

CLEANING UP
Clean all equipment with Dulux Thinner 850 - 761 immediately after use.
FILM THICKNESS

Wet: 100 - 150 micro-metres.
Dry: 50 - 75 micro-metres..

 
Application Method65° spraying tip1-2 hours drying timePractice proper cleaning
PRE - APPLICATION
SURFACE PREPARATION

Surfaces generally must be clean, dry, free from all defective or poorly adhering material, dirt, grease, wax etc.
Steel surfaces should be blast-cleaned to BS 7079 Part A1: 1989. Sa 2.5 to give an appropriate surface profile.

SYSTEM INFORMATION
Metal

Wood and Masonry
PRIMER (1 COAT)

Dulux Epoxy Zinc Phosphate Primer (A580 - 16252)
Dulux Epoxy Primer Off White A580 - PJ - 0529
FINISH (2 COATS)

Dulux Epoxy Chemical Resistant Finish (A430)

Note: It is important to ensure that the substrate temperature is at least 3°C above dew point. The minimum temperature for application is 10°C. Relative humidity should not exceed 85%. Where primer or intermediate coat of Dulux Epoxy Chemical Resistant Finish has been left exposed over a period of time it will be necessary to thoroughly prepare the surface by removing all dirt, grease oil, wax, rust, salts etc before the overpainting. Where rusting of peaks has occurred on blast cleaned steel, flash blasting or thorough manual preparation followed by spot priming with an appropriate primer will be required.
 
Use abrasive paperDust off
PRECAUTION
SAFETY, HEALTHY AND ENVIRONMENTAL INFORMATION

FLAMMABLE
Harmful by inhalation and in contact with skin.
Irritating to eye.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
If swallowed seek medical advice immediately and show this container or label.
If swallowed, rinse mouth with water (Only if person is conscious).
Keep away from food, drinks, animal feed and out of the reach of children.
Keep away from combustible material.
Container must be stored in a cool and shaded place.
It must be tightly closed in a secure, upright position.
Do not breathe dust.
Work in a well-ventilated area and do not breathe in vapour or spray.
When applying paint, wear suitable protective clothing, gloves and eye/face protection.
In case of fire use foam, dry powder, AFFF, CO2 - Never use water.
In case of a spillage, contain and collect spillage using sand or earth and do not empty into watercourses, drains or the environment.
Dispose of any paint waste in accordance with the appropriate Environmental Quality Regulations
Refer to Dulux Product Safety Data Sheet for further details.
In case of emergency, refer to Emergency Incident Response Hotline 1800 80 6187.

 
Keep seal tightStore in cool placeSecure 

uprightWear proper protectionEnsure good ventilationPractice 

proper disposalWear proper protection


An AkzoNobel group of company
Trade Professional
Dulux Trade Paint Specification
Colour Selector
Mouse Painter
Colour Palette4 Explorer
Professional Trade Enquiry
Trade Professional  |  Store  |  Sitemap  |  Legal Notices  |  Colour Accuracy  |  Privacy Policy  |  Other ICI Websites