PERFORMANCE GUIDE
|
FILM PROPERTIES
Water Resistance
|
Resistant to mild atmospheric fume attack and to the salts in new mortar, rendering and similar surfaces.
Resistant to the levels of atmospheric humidity normally experienced in exterior environment.
|
THEORECTICAL COVERAGE
|
The spreading capacity of this product will vary considerably according to the roughness and porosity of the surface. On smooth surfaces of average porosity 12 - 13 m²/litre.
|
PRODUCT DATA
|
COMPOSITION
(nominal)
|
Pigment : Lightfast Non-Lead Pigments and Mineral Extenders.
Blinder : Acrylic Emulsion.
Solvent : Water
|
VOLUME SOLIDS
|
White 40% (nominal), other colours will vary.
|
APPLICATION
|
THINNING
Brush or Roller
Conventional Spray
Airless Spray
|
For sealing new or bare surfaces, thin with up to 1 part of clean water to 10 parts of paint (10%).
For normal use, thinning is usually not necessary.
Add up to 1 part of clean water to 3 parts of paint (30%).
Ready to use. Thinning is usually not required.
|
SPRAY RECOMMENDATIONS
Conventional Spray
Airless Spray
|
Satisfactory through most equipment.
A typical set up for airless spray application would be a minimum working pressure on paint of 140Kg/cm² (2000 lb/sq in) with a spray tip size 0.58mm (23 thou) and a spray tip angle 65°
|
DRYING TIMES
Touch Dry
Recoat
|
Single coat at standard thickness:
Dependant on temperature and humidity.
2 - 3 hours.
|
CLEANING UP
|
Clean all equipment with clean water immediately after use.
|
|
   
|
PRE - APPLICATION
|
SURFACE PREPARATION
|
Allow all new surfaces to dry out completely. Remove all loose or defective paint or powdery residues by thorough brushing and scraping, using a stiff fiber brush or high pressure water jet. Treat any areas affected by mould, lichens, algae and moss with Dulux Fungicidal Wash. Make good minor defects with a suitable exterior grade Filler. Use a sand and cement mix for larger holes and cracks. Allow to dry. Surfaces that remain powdery, friable or chalky after thorough preparation should be sealed with a coat of Dulux Adhesion Promoting Wall Sealer.
Note: Do not apply Dulux Weathershield Acrylic Exterior Wall Finish during wet weather.
|
SYSTEM INFORMATION
Powdery Surfaces
Alkaline and New Surfaces
Normal, Sound Surfaces
|
PRIMER (1 COAT)
Dulux Weathershield Prime (A579-15222)
Dulux Weathershield
Wall Sealer (A931 - 18177)
A thinned first coat of
Dulux Weathershield (A910)
|
FINISH (2 COATS)
Dulux Weathershield (A910)
|
|
|
   
|
PRECAUTION
|
SAFETY, HEALTHY AND ENVIRONMENTAL INFORMATION |
Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
May cause sensitisation by skin contact.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice
To remove splashes of paint from skin, use soap and water or a recognised cleanser.
Keep away from food, drinks, animal feed and out of the reach of children.
Container must be stored in a cool and shaded place
It must be tightly closed in a secure, upright position
Work in a well ventilated area and do not breathe in vapour or spray
A suitable mask should be worn during sanding
When applying paint, it is advisable to wear eye protection and suitable gloves
In case of a spillage, contain and collect spillage using sand or earth and do not empty into water courses, drains or the environment
Dispose of any paint waste in accordance with the appropriate Environmental Quality Regulations
Refer to Dulux Product Safety Data Sheet for further details
In case of emergency, refer to Emergency Incident Response Hotline 1800 80 6187.
|
|
     
|