Home : Products
: High Performance Paints : Interior : TRU-GLAZE-WBTM
4408 Waterborne Epoxy Gloss Coating
|
|
TRU-GLAZE-WBTM 4408 D4408-B Line (High
Performance - Waterborne)
Waterborne Epoxy Gloss Coating
|
|
A high performance, two-component chemically-cured
waterborne gloss epoxy coating for use as a hard, durable high
performance architectural coating (HIPAC).
USAGE
For use on interior properly prepared poured concrete, concrete
block, drywall, metal, wood. Ideal for hard usage areas of
schools, hospitals, restaurants, public buildings and factories.
May be used in areas subject to continuous high moisture such as
shower rooms.
Special Qualifications
Suitable for use on structural surfaces where there is a
possibility of incidental food contact in commercial food
preparation establishments, food processing plants and federally
inspected meat and poultry plants. USDA no longer requires or
furnishes product certification letters.
BENEFITS
- Chemical and stain resistant.
- Resists splash and spillage of alkalis, salts,
moisture, oils, grease, foodstuffs, and detergents.
- Abrasion resistant.
- Low door and high flash point.
- Use over alkyd, latex or epoxy coatings.
- Long lasting tile-like finish.
- Easily washed and cleaned.
- Low VOC.
- Performance alternate for Federal Specifications TT -
C - 535B (Type II) and TT - C - 550C (Class A).
LIMITATIONS OF USE
Not recommended for immersion service. Exterior exposure will
cause early dulling and loss of gloss, but does not affect
protective properties. Epoxy coatings may yellow during
application and cure if exposed to the combustion by-products of
improperly vented fossil fuel burning heaters.
PACK SIZE 5 litres units comprising Base: 2.5
litres and Converter: 2.5 litres.
COLOUR RANGE White and custom colours.
|

Download Product Information
|
PERFORMANCE
GUIDE
|
FILM PROPERTIES
Abrasion Resistance
Pencil Hardness
Flexibility
Impact Resistance
Chemical/Stain Resistance
|
Good
Good
Excellent
Excellent
Excellent
Excellent
|
THEORECTICAL COVERAGE
|
A guide to the
theoretical coverage which can be achieved under normal
conditions is 10.5 - 11.5m²/litre
|
PRODUCT
DATA
|
COMPOSITION
(nominal)
|
Pigment : Lightfast Non-Lead Pigments and Mineral
Extenders.
Binder : Polyamide Cured Epoxy.
Solvent : Aromatic Hydrocarbon and Alcohol.
|
Weight/Litre
|
1.21 kg/L -
varies with colour
|
VOC (EPA 24)
|
206 g/L -
varies with colour
|
Volume Solids
|
43% ± 1%
- varies with colour. |
Theorectical Coverage
|
17m²/L at
25 µm dry.
|
Practical Coverage
|
Apply at 6 -
8m²/L on smooth sealed surfaces. Actual coverage may vary
depending on substrate and application method. When applying
by spray, losses due to overspray can be heavy on narrow
sections.
|
Service Temperature Limits
|
121°C in
air.
|
Flame Spread Rating
|
Class A (0-25)
over non-combustible surfaces.
|
Shelf Life
|
1 year minimum
- unopened.
|
Mix Ratio By Volume
|
1 (Base): 1
(Converter)
|
Induction Time
|
30 minutes.
|
Pot Life
|
Up to 8 hours
at 25°C.
|
Flash Point
|
96°C.
|
APPLICATION
|
THINNING
|
Thinning is not
normally required. However, if necessary add up to 1 part of
water to 10 parts of paint (10%). |
SPRAY RECOMMENDATIONS
Conventional Spray
Airless Spray
|
Satisfactory through most equipment.
A typical set up for airless spray application is a minimum
working pressure on paint of 3000psi (207 bars) with a spray
tip size 0.015". |
CURING TIMES
Recoat 25°C
Hard Dry
|
Single coat at
standard thickness:
Overnight.
7 days. |
CLEANING UP
|
Clean
immediately after use with warm, soapy water. Rinse pumps and
hoses with xylene after cleaning. |
FILM THICKNESS
|
Wet: 115 - 290 micro-metres.
Dry: 50 - 125 micro-metres.
|
| PRE -
APPLICATION |
SURFACE PREPARATION
|
All surfaces
must be sound, clean, dry, and free of oil, grease, dirt,
mildew, form release agents, curing compounds, efflorescense,
loose and flaking paint and other foreign matter. |
SYSTEM INFORMATION NEW SURFACES
Concrete, Plaster, and Masonry
Drywall
Wood
Steel
Galvanized Metal and Aluminium
Glazed Brick, Ceramic Tile and Fibreglass
|
Cure at least 30 days before painting. pH must be 10.0 or
lower. Remove laitance and roughen unusually slick poured or
precast concrete by acid etching or sandsweeping. Follow
acid manufacturer's application and safety instructions.
Rinse thoroughly with water and allow to dry. Remove loose
aggregate. Prime with this product thinned 8:1 with water or
prime with waterborne epoxy primer TRU-GLAZE-WB 4030. Dry
overnight to recoat. Fill concrete block in areas not
subject to moisture with latex filler. In moisture prone
areas, fill with this product. Fillers must dry overnight
before coating.
Prime with this product or waterborne epoxy primer
TRU-GLAZE-WB 4030 primer.
Prime with this product.
Prime with waterborne epoxy primer TRU-GLAZE-WB 4030.
Prime with waterborne epoxy primer TRU-GLAZE-WB 4030.
Scuff sand and prime with waterborne epoxy primer
TRU-GLAZE-WB 4030. |
|
PREVIOUSLY PAINTED SURFACES
|
The waterborne
components of this product generally allow use over most old
coatings. Old coatings should be tested for lifting. If they
lift, remove them. Wash to remove contaminants. Rinse
thoroughly with water and allow to dry. Dull glossy areas by
light sanding. Remove sanding dust. Remove loose paint. Prime
bare areas with primer specified under New Surfaces. |
PRECAUTION
|
SAFETY, HEALTHY AND ENVIRONMENTAL INFORMATION
|
D4408-BASE
IRRITANT
Irritating to eyes, respiratory system and skin.
Avoid contact with skin/eyes.
May cause sensitisation by skin contact.
If swallowed seek medical advice immediately and show this
container or label.
If swallowed, rinse mouth with water (Only if person is
conscious).
In case of contact with eyes, rinse immediately with plenty of
water and seek medical advice.
To remove splashes of paint from skin, use soap and water or a
recognised cleanser.
Keep away from food, drinks, animal feed and out of the reach
of children.
Keep away from combustible material.
Container must be stored in a cool, shaded place and tightly
closed in a secure, upright position.
Take precautionary measures against static discharges.
Work in a well-ventilated area and do not breathe in vapour or
spray.
When applying paint, wear suitable protective clothing, gloves
and eye/face protection.
In case of fire use foam, dry powder, AFFF, CO2 - Never use
water.
In case of a spillage, contain and collect spillage using sand
or earth and do not empty into watercourses, drains or the
environment.
Dispose of any paint waste in accordance with the appropriate
Environmental Quality Regulations.
Refer to Product Safety Data Sheet for further details.
In case of emergency, refer to Emergency Incident Response
Hotline 1800 80 6187.
D4408-CONVERTER
Avoid contact with skin/eyes.
If swallowed seek medical advice immediately and show this
container or label.
In case of contact with eyes, rinse immediately with plenty of
water and seek medical advice.
To remove splashes of paint from skin, use soap and water or a
recognised cleanser.
Contains: ALIPHATIC GLYCIDYLETHER. May produce an allergic
reaction.
Keep away from food, drinks, animal feed and out of the reach
of children
Keep away from combustible material.
Container must be stored in a cool, shaded place and tightly
closed in a secure, upright position.
Take precautionary measures against static discharges.
Work in a well-ventilated area and do not breathe in vapour or
spray.
When applying paint, wear suitable protective clothing, gloves
and eye/face protection.
In case of fire use foam, dry powder, AFFF, CO2 - Never use
water.
In case of a spillage, contain and collect spillage using sand
or earth and do not empty into watercourses, drains or the
environment.
Dispose of any paint waste in accordance with the appropriate
Environmental Quality Regulations.
Refer to Product Safety Data Sheet for further details.
In case of emergency, refer to Emergency Incident Response
Hotline 1800 80 6187.
|
|
|

|

|
|