A high perfomance, two-component chemically-cured waterborne gloss epoxy coating for use as a hard, durable high performance architectural coating (HIPAC)

USAGE
For use on interior properly prepared poured concrete, concrete block, drywall, metal, wood. Ideal for hard usage areas of schools, hospitals, restaurants, public buildings and factories. May be used in areas subject to continuous high moisture such as shower rooms.

Special Qualifications
Suitable for use on structural surfaces where there is a possibility of incidental food contact in commercial food preparation establishments, food processing plants and federally inspected meat and poultry plants. USDA no longer requires or furnishes product certification letters.

BENEFITS

  • Chemical and stain resistant.
  • Resists splash and spillage of alkalis, salts, moisture, oils, grease, foodstuffs, and detergents.
  • Abrasion resistant.
  • Low odor and high flash point.
  • Use over alkyd, latex or epoxy coatings.
  • Long lasting tile-like finish.
  • Easily washed and cleaned.
  • Low VOC.
  • Performance alternate for Federal Specifications TT - C535B (Type II) and TT - C - 550C (Class A).

PACK SIZE 5 litre units comprising Base: 2.5 litre and Converter:2.5 litre

COLOUR RANGE White and custom colours


Dulux Sterishield Waterborne Epoxy Gloss Coating (D4408-B Line)


Download Product Data Information
PERFORMANCE GUIDE
FILM PROPERTIES
Abrasion Resistance
Pencil Hardness
Flexibility
Impact Resistance
Water Resistance
Chemical/Stain Resistance
Good
Good
Excellent
Excellent
Excellent
Excellent
PRODUCT DATA
COMPOSITION
(nominal)

Weight/Litre
VOC (EPA 24)
Volume Solids
Theorectical Coverage

Service Temperature Limit
Flame Spread Rating
Shelf Life
Mix Ratio By Volume
Induction Time
Pot Life
Flash Point
Pigment : Lightfast Non-Lead Pigments and Mineral Extenders.
Blinder : Polyamide Cured Epoxy..
Solvent : Aromatic Hydrocarbon and Alcohol.
1.21 kg/L - varies with colour
206 g/L - varies with colour
43% ± 1% - varies with colour
A guide to the theorectical coverage which can be achieved under normal conditions is 3.44 - 8.6m²/L. When applying by spray, looses due to overspray can be heavy on narrow sections.
121°C in air.

Class A (0-25) over non-combustible surfaces.
1 year minimum - unopened.
4 (Base) : 1 (Converter)
30 minutes.
Up to 8 hours at 25°C.
96°C.
APPLICATION
THINNING
Thinning is not normally required. However, if necessary add up to 1 part of water to 10 parts of paint (10%).
SPRAY RECOMMENDATIONS
Conventional Spray
Airless Spray


Satisfactory through most equipment.
A typical set up for airless spray application would be a minimum working pressure on paint of 3000 psi (207 bars) with a spray tip size 0.015".
CURING TIMES
Recoat at 25°C
Full cure
Single coat at standard thickness:
Overnight.
7 days.
CLEANING UP
Clean immediately after use with warm, soapy water. Rinse pumps and hoses with xylene after cleaning.
FILM THICKNESS
Wet: 115 - 290 microns
Dry: 50 - 125 microns
PRE - APPLICATION
SURFACE PREPARATION
All surfaces must be sound, clean, dry, and free of oils, grease, dirt, mildew, form release agents, curing compounds, efflorescense, loose and flaking paint and other foreign matter.
SYSTEM INFORMATION NEW SURFACES
Concrete, Plaster, and Masonry






Drywall
Wood
Steel
Galvanized Metal and Aluminium
Glazed Brick, Ceramic Tile and Fiberglass
PREVIOUSLY PAINTED SURFACES



Cure at least 30 days before painting. pH must be 10.0 or lower. Remove laitance and roughen usually slick poured or precast concrete by acid etching or sandsweeping. Follow acid manufacturer's application and safety instructions. Rinse thoroughly with water and allow to dry. Remove loose aggregate Prime with this product thinned 8:1 with water or prime with waterborne epoxy primer. Dry overnight to recoat. Fill concrete block in areas not subject to moisture with latex filler. In moisture prone areas, fill with this product. Fillers must dry overnight before coating.
Prime with this product or waterborne epoxy primer.
Prime with this product.
Prime with waterborne epoxy primer.
Prime with waterborne epoxy primer.

Scuff sand and prime with waterborne epoxy primer.


The waterborne components of this product generally allow use over most old coatings. Old coatings should be tested for lifting. If they lift, remove them. Wash to remove contaminants. Rinse thoroughly with water and allow to dry. Dull glossy areas by light sanding. Remove sanding dust. Remove loose paint. Prime bare areas with primer specified under New Surfaces.
PRECAUTION
SAFETY, HEALTHY AND ENVIRONMENTAL INFORMATION
D4408B-BASE
IRRITANT
Irritating to eyes, respiratory system and skin.
Avoid contact with skin/eyes.
May cause sensitisation by skin contact.
If swallowed seek medical advice immediately and show this container or label.
If swallowed, rinse mouth with water (Only if the person is conscious).
In case of contact with eyes, rinse immediately with plenty of water or a recognised cleanser.
To remove splashes of paint from skin, use soap and water or a recognised cleanser.
Keep away from food, drinks, animal feed and out of the reach of children.
Keep away from combustible material.
Container must be stored in a cool, shaded place and tightly closed in a secure, upright position.
Take precautionary measures against static discharges.
Work in a well ventilated area and do not breathe in vapour, spray or dust.
When applying paint, wear suitable protective clothing, gloves and eye/face protection.
In case of fire use foam, dry powder, AFFF, CO2 - Never use water.
In case of a spillage, contain and collect spillage using sand or earth and do not empty into water courses, drains or the environment.
Dispose of any paint waste in accordance with the appropriate Environmental Quality Regulations.
Refer to Product Safety Data Sheet for further details.
In case of emergency, refer to Emergency Incident Response Hotline 1800 80 6187.

DD4408B-CONVERTER
Avoid contact with skin/eyes.
If swallowed seek medical advice immediately and show this container or label.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice
To remove splashes of paint from skin, use soap and water or a recognised cleanser.
Contains: ALIPHATIC GLYCIDYLETHER. May produce an allergic reaction.
Keep away from food, drinks, animal feed and out of the reach of children
Keep away from combustible material.
Container must be stored in a cool, shade place and tightly closed in a secure, upright position.
Take precautionary measures against static discharges.
Work in a well ventilated area and do not breathe in vapour, spray or dust.
When applying paint, wear suitable protective clothing, gloves and eye/face protection.
In case of fire use foam, dry powder, AFFF, CO2 - Never use water.
In case of a spillage, contain and collect spillage using sand or earth and do not empty into water courses, drains or the environment.
Dispose of any paint waste in accordance with the appropriate Environmental Quality Regulations.
Refer to Product Safety Data Sheet for further details.